SIEMENS

  You are in the USA [change]

MAGNETOM Concerto 0.2T Images

 
  • Site Explorer
  • Contact
  • Healthcare
  • Products & Solutions
    • Detection & Diagnosis
    • Accessory Solutions
    • Information Technology
    • Therapy Systems
    • Ventilation & Anesthesia
    • Clinical Specialties
    • Performance & Financial Solutions
  • Detection & Diagnosis
    • Angiography
    • Computed Tomography
    • Fluoroscopy
    • Magnetic Resonance
    • Mammography
    • Molecular Imaging
    • Nuclear Medicine/PET
    • Radiography
    • Refurbished Systems
    • Surgery Systems
    • Ultrasound
  • Magnetic Resonance
    • MAGNETOM Family
    • Meet Tim
  • MAGNETOM Family
    • MAGNETOM Verio 3T
    • MAGNETOM ESSENZA 1.5T
    • MAGNETOM Avanto 1.5T
    • MAGNETOM Trio, A Tim System 3T
    • MAGNETOM Espree 1.5T
    • MAGNETOM Symphony 1.5T
    • MAGNETOM C! 0.35T
  • MAGNETOM Concerto 0.2T

MAGNETOM Concerto 0.2T Images


  • Head imaging for diagnosis of intracranial mass
  • High resolution 512 image
  • Superior T1 contrast, acquired with a 3D data set


  • Head, 3D T1 FLASH coronal, astrocytoma, TR 20 ms, TE 8.9 ms, TA 3:52 min, partitions 20, matrix 256, FoV 256 mm, coil CP Head Array

    Courtesy of Dr. Tan, Dr. Basato, Cardinal MRI Center, Philippines

    syngo MR Neuro

  • At low-field HASTE Diffusion is superior to EPI and Line Scan
  • ADC Map calculated from images with b=0 s2/mm and b=600 s2/mm


  • Head, Diffusion b = 0 trace, T2 HASTE transversal
    TR 4000 ms, TE 107 ms, TA 0.63 s, SL 7 mm, slices 17, matrix 128, FoV 250 mm, coil HE

    Courtesy of NKTI, Manila, Philippines

    C-Spine imaging for diagnosis of syringomyelia

  • Restore magnetization restoration for excellent T2 contrast in short acquisition times
  • Flexible adjustment of FoV with combinable Head and Neck Array coils


  • C-spine, T2 TSE Restore sagittal, syringomelia, TR 4200 ms, TE 120 ms, TA 2:31 min, SL 3 mm, slices 12, matrix 512i, FoV 300 mm, coils HE, NM

    Courtesy of Instituto de Radiologia, Sao Paulo, Brazil

    300 mm large FoV with C-IPA

  • Ce-MRA without venous contamination
  • CP Head/Neck Array coil combination


  • Carotids angio, 3D FLASH ce-MRA, MIP, right brachiostenosis, TR 7.4 ms, TE 2.4 ms, TA 26 s, eff SL 1.3 mm, partitions 56, matrix 256, FoV 300 mm, coils HE, NE

    Courtesy of Tai-Chung Hospital, Taiwan

    Excellent l-spine in clinical routine

  • 512 matrix, 4 mm slice thickness


  • L-spine, T2 TSE sagittal, metastasis of adeno carcinoma, TR 4500 ms, TE 134 ms, TA 6:54 min, SL 4 mm, slices 11, matrix 512, FoV 300 mm, coils BO, SP

    Courtesy of Vikram Imaging Mysore, India

    Ultrafast 1.8 s/slice TrueFISP lung imaging

  • Excellent visualization of broncho-vessels and lung fields


  • Lung T2 TrueFISP, breath-hold, logarithm, TR 4.9 ms, TE 2.4 ms, TA 3:03 min, SL 15 mm, slices 3, matrix 256, FoV 350 mm, coils BO, SP

    Courtesy of Prof. Ruggiero, Center Ester Bara, Italy

    Easy and comfortable abdominal imaging with Siemens unique 2D PACE motion correction

  • Free breathing abdominal study without respiratory belt


  • Abdomen, T2 TSE coronal, liver cysts, TR 4408.8 ms, TE 91 ms, TA 2 x 4:08 min, Sl 7mm, slices 16, matrix 512i, FoV 370 mm, coil BS

    Courtesy of Instituto de Radiologia, Sao Paulo, Brazil

    syngo MR Body

  • Triple contrast Turbo Spin Echo for the assessment of liver lesions – three contrasts (with different Echo Times) in one scan

  • Available with 2D PACE multi directional motion correction for free breathing studies without respiratory belt


  • Liver, T2 TSE transversal, triple contrast
    TR 3827.7 ms, TE 132 ms, TA 11:12 min, SL 8 mm, slices 48, matrix 512, FoV 320 mm, coil BS

    Courtesy of Tai-Chung Hospital, Tai-Chung, Taiwan

    syngo MR Body

  • Quick assessment of the biliary system in a 2 s breath-hold with single shot HASTE protocols


  • Gallbladder, MRCP, T2 HASTE
    TR 2800 ms, TE 889 ms, TI 100 ms, TA 1.93 s, SL 60 mm, slice 1, matrix 512i, FoV 256 mm, coil BS

    Courtesy of Arihant Diagnosis, Varanasi, India

    Excellent shoulder imaging

  • Orthopedic imaging using water excitation for fat suppression
  • Region of interest always iso center with 2D table movement


  • Shoulder, 3D T1 FLASH coronal, FatSat, water excitation, TR 31 ms, TE 10.3 ms, TA 7:56 min, eff. SL 4 mm, partitions 30, matrix 512, FoV 165 mm, coil SH

    High field sequences at low-field

  • T2 imaging with low-fat signal with T2 MEDIC sequence
  • Fast high resolution scans with Multi Echo sequences


  • Elbow, 3D T2 MEDIC, transversal
    TR 62 ms, TE 36 ms, TA 5:40 min, eff. SL 4 mm, partitions 16, matrix 512i, FoV 109 mm, coil EX

    syngo MR Ortho

  • Thin slices and high in-plane resolution for imaging of the Wrist
  • Anatomically shaped Wrist Coil


  • Wrist, T2 FLASH coronal
    TR 450 ms, TE 17 ms, TA 5:01 min, SL 3 mm, slices 12, matrix 512i, FoV 160 mm, coil M11

    Courtesy of Primus, Guwahati, India

    Click to CallClick to Chat

    Product Details

    • Overview
    • Business
    • Clinical Application
    • Patient Benefits
    • Technical Specifications

    Information Gallery

    • Images
    • Clinical Methods

    Customer Care

    • Education

    Related Products & Services

    • Coils
    • Clinical Applications
    • Upgrades
    • FAQs MAGNETOM Concerto
      Close  



      Close  



    © Siemens AG, 2002-2008. All rights reserved | Customer Relations Policy | Privacy Statement | Terms of Use
    • Print this page
    • Email this page