The new gold standard in volume imaging for ultrasound. The ACUSON SC2000™ volume imaging ultrasound system introduces a new paradigm in cardiac imaging and workflow, transforming your echocardiography practice and giving you the power to see more — instantly.
ACUSON SC2000 image gallery
Volume echocardiography: ACUSON SC2000 system's instantaneous full-volume imaging.
Powerful new architecture and innovative Coherent Volume Formation technology enable Echo in a Heartbeat™ — true full-volume imaging for every patient.
Unlike traditional 3D ultrasound systems that require four to seven heart cycles to stitch together a volume, the ACUSON SC2000 ultrasound system delivers instantaneous full-volume acquisition for improved workflow and better outcomes.
Full volume imaging, 90 degrees x 90 degrees up to 40 volumes per second at 16 cm depth,. No more ECG gating, no more breath holding, no more uncertainty. Derived reference plane images from the real-time full volume cardiac dataset give you more information in less time.
Accelerate your workflow. eSieScan workflow protocol increases reproducibility and consistency of an echo exam. Knowledge-based workflow software uses learned pattern recognition and an expert database of real clinical cases to recognize anatomical patterns and landmarks as well as perform automatic measurements.
Compact and highly mobile, the system adapts to all clinical environments, providing you with the ultimate in simple and stress-reduced operation. The 4Z1c transducer supports volume imaging, 2D, spectral Doppler, color Doppler and LVO contrast*. It features a patented ergonomic Palmar grip designed to reduce repetitive stress injuries.
Advanced next-generation architecture is strengthened by breakthrough technologies. Coupled with high volume rate acquistion, Coherent Volume Formation technology delivers excellent image resolution. Advanced cardiovascular applications and compliance with 3D DICOM Open Standard extend the versatility of this next generation system.
ACUSON SC2000 volume imaging ultrasound system
Instantaneous, full-volume imaging has arrived. It’s real. It’s proven. It’s now.
Join us to see into the shape of tommorow—the exciting new technology we call Echo in a Heartbeat.
Annual Cardiac Imaging Course and Meeting
28-30 May, Madrid Spain
American Society of Echocardiography
June 6-10, Washington DC U.S.A.
Annual Congress of the Swiss Society of Cardiology
10-12 June, Lausanne Switzerland
Leipzig Echokardiography Symposium
18 June, Leipzig Germany
Echocardiography Today and Tommorrow
22-26 June, St. Wolfgang Austria
European Society of Cardiology
29 Aug-2 September, Barcelona Spain
*At the time of publication, the U.S. Food & Drug Administration has cleared ultrasound contrast agents only for use in LVO. Check the current regulation for the country in which you are using this system for contrast agent clearance .