SIEMENS

  You are in the USA [change]

CT Cardiac Engine

 
  • Site Explorer
  • Contact
  • Healthcare
  • Products & Solutions
    • Detection & Diagnosis
    • Accessory Solutions
    • Information Technology
    • Therapy Systems
    • Ventilation & Anesthesia
    • Clinical Specialties
    • Performance & Financial Solutions
  • Detection & Diagnosis
    • Angiography
    • Computed Tomography
    • Fluoroscopy
    • Magnetic Resonance
    • Mammography
    • Molecular Imaging
    • Nuclear Medicine/PET
    • Radiography
    • Refurbished Systems
    • Surgery Systems
    • Ultrasound
  • Computed Tomography
    • Dual Source CT
    • Multislice CT
    • Open Bore CT
    • CT Clinical Engines
    • Clinical Applications
    • Workflow
  • CT Clinical Engines
    • CT Oncology Engine
    • CT Neuro Engine
    • CT Cardiac Engine
    • CT Acute Care Engine
  • CT Cardiac Engine

CT Cardiac Engine

/siemens/en_US/gg_ct_FBAs/images/application_images/clinical_engines/ct_cardiac_engine_h6.jpg

The Complete Solution for cardiovascular CT

The CT Cardiac Engine offers you the complete solution for cardiovascular CT imaging.

From scan to diagnosis, your CT Cardiac Engine provides everything you need to achieve a streamlined cardiovascular workflow. State-of-the- art ECG-synchronized acquisition, image reconstruction techniques and intuitive ECG-editing to adapt for arrhythmia before image reconstruction ensuring optimal image quality. With your patients' safety in mind, the lowest posible dose is provided with intelligent adaptive ECG-pulsing. An innovative, dedicated cardiovascularimaging user interface simplifies your daily workflow and ensures highest throughput.

syngo will help you deliver excellent diagnostic outcomes with dedicated software solutions that cover the field of cardiovascular imaging: from vascular analysis with accurate stenosis measurement to stent planning, from cardiac morphology to coronary artery stenosis measurement, to functional analysis resulting in a comprehensive report that turns data into a diagnostic outcomes within minutes.

Scanner solutions1

  • Fastest available rotation time with up to 0.33 sec rotation delivers highest temporal resolution and fastest volume coverage.
  • z-SharpTM Technology ensures the industry’s highest spatial resolution of less than 0.4 mm for exceptional visualization of the complex coronary and vascular anatomy.
  • HeartView CT and HeartView DSCT2 provide Siemens proprietary ECG-gated acquisition and reconstruction techniques to ensure optimal cardiac image quality.
  • Fully integrated ECG device facilitates both prospective triggering and retrospective gating, plus ECG-pulsing for maximum dose reduction in cardiac exams.
  • New adaptive2 ECG-pulsing allows even further dose reduction, even in patients with irregular heart rates.
  • Intuitive ECG-editing tool adapts for extra beats in arhythmic situations, ensuring optimal retrospective image reconstruction.
  • CARE Dose4DTM delivers the highest possible image quality at the lowest possible dose for all vascular exams – maximum detail, minimum dose.

syngo solutions

General workflow

  • Direct 3D reconstruction from raw data delivers the best possible image quality in the shortest possible time.
  • Intuitive Cardiac UI for ECG-gated acquisition and reconstruction.
  • Concurrent multiphase reconstructions within one recon job brings exceptional speed into your cardiac workflow.
  • Fast data transfer to the syngo workplace of your choice.

Cardiac Evaluation

syngo Circulation and syngo Calcium Scoring – a complete guided cardiac evaluation in under 10 minutes.

  • Fast loading of multiple cardiac phases.
  • Standard angiographic projections with free 3D rotation and automated heart isolation.
  • 1-click segmentation of the coronary arteries.
  • Guided quantitative coronary assessment – identify, quantify and report calcified/noncalcified lesions with fully integrated stent planning.
  • Fully automated cardiac function evaluation – robust measurement of EF and stroke volume with automatic ES and ED detection.
  • Automatically updated cross-sectional view of the vessel (IVUS View).
  • Cine display and recording of cardiac phases facilitates myocardium and valve evaluation.
  • Automated calcium scoring (Agatston score, volume and mass) for lesions of the main branches.
  • Flexible, intelligent reporting, including DICOM structured report and various output formats, e.g. PDF, HTML.

Vascular Evaluation

syngo InSpace4D with Advanced Vessel Analysis – exceptional speed and image quality for quantitative vascular diagnosis and planning of intervention.

  • Advanced Vessel Analysis with 1-click segmentation, automated center line and automated stenosis quantification including exclusion of calcium and existing stents.
  • Advanced bone removal with 1-click segmentation of bony structures, plus bone transparency mode.
  • Robust measuring tools in 2D and 3D.
  • Simultaneous loading of 2 datasets for parallel display and improved follow-up.


1 Depends on system configuration.
2 Only available on SOMATOM Definition.

  Close  